Enerpan's new Tank Panel system has been designed from the ground up to specifically meet the mechanical challenges presented by insulating a LIQUID storage tank

Enerpan's Tank panels use a single Aluminum face for better shape conformation, while our special crimped joint and cable system provides a seal that stays water-tight, yet gives during thermal expansion. The type of insulation used is furthermore customized to the operating temperature of the tank.

Functional Specs
Exoskeleton 3105-H14 Aluminum Sheet, .024 inch thick
Single face, stucco embossed
Insulating Core Flexible polyurethane foam, foil backed, and/or Mineral Wool
1.5-4 inches thickness, panels can be ordered in 1/2 inch increments
Width 24 inches
Both edges are fully lipped with Enerpan crimp-seal joint
Length 48 feet max
Panel length is manufactured to customer specification
Finish Silicone modified polyester in 30 colors
Interior surfaces sealed with a corrosion-resistant epoxy clearcoat
R-Value 7.8 per inch of thickness
 
Technical Specs - Foam
Temperature range up to 120 ºF
Mineral wool is used for temperature ranges which exceed 120 ºF
Support Cable system
No support rings required
Environmental Data HCFC Free compliant
ASTMC 1289 Type 1
 
Technical Specs - Mineral Wool
Temperature range 120 ºF +
Support Support rings required
Max Service Temperature 1200 ºF / 650 ºC
ASTM C 411
Dimensional Stability 1.49% (linear shrinkage at 650 ºC)
ASTM C 356
Moisture Resistance 0.01% moisture sorption
ASTM C 1104
Thermal Resistance 4.0 hr.ft ².F/Btu (R-Value/inch @ 75 ºF)
0.71m² K/W (RSI value/25.4 mm @ 24 ºC)
ASTM C 518 (C 177)
Lifespan 20 years +